Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 136.580
1.
BMC Neurol ; 24(1): 144, 2024 May 09.
Article En | MEDLINE | ID: mdl-38724916

BACKGROUND: Restoring shoulder function is critical for upper-extremity rehabilitation following a stroke. The complex musculoskeletal anatomy of the shoulder presents a challenge for safely assisting elevation movements through robotic interventions. The level of shoulder elevation assistance in rehabilitation is often based on clinical judgment. There is no standardized method for deriving an optimal level of assistance, underscoring the importance of addressing abnormal movements during shoulder elevation, such as abnormal synergies and compensatory actions. This study aimed to investigate the effectiveness and safety of a newly developed shoulder elevation exoskeleton robot by applying a novel optimization technique derived from the muscle synergy index. METHODS: Twelve chronic stroke participants underwent an intervention consisting of 100 robot-assisted shoulder elevation exercises (10 × 10 times, approximately 40 min) for 10 days (4-5 times/week). The optimal robot assist rate was derived by detecting the change points using the co-contraction index, calculated from electromyogram (EMG) data obtained from the anterior deltoid and biceps brachii muscles during shoulder elevation at the initial evaluation. The primary outcomes were the Fugl-Meyer assessment-upper extremity (FMA-UE) shoulder/elbow/forearm score, kinematic outcomes (maximum angle of voluntary shoulder flexion and elbow flexion ratio during shoulder elevation), and shoulder pain outcomes (pain-free passive shoulder flexion range of motion [ROM] and visual analogue scale for pain severity during shoulder flexion). The effectiveness and safety of robotic therapy were examined using the Wilcoxon signed-rank sum test. RESULTS: All 12 patients completed the procedure without any adverse events. Two participants were excluded from the analysis because the EMG of the biceps brachii was not obtained. Ten participants (five men and five women; mean age: 57.0 [5.5] years; mean FMA-UE total score: 18.7 [10.5] points) showed significant improvement in the FMA-UE shoulder/elbow/forearm score, kinematic outcomes, and pain-free passive shoulder flexion ROM (P < 0.05). The shoulder pain outcomes remained unchanged or improved in all patients. CONCLUSIONS: The study presents a method for deriving the optimal robotic assist rate. Rehabilitation using a shoulder robot based on this derived optimal assist rate showed the possibility of safely improving the upper-extremity function in patients with severe stroke in the chronic phase.


Electromyography , Exoskeleton Device , Feasibility Studies , Muscle, Skeletal , Shoulder , Stroke Rehabilitation , Humans , Male , Female , Stroke Rehabilitation/methods , Middle Aged , Aged , Shoulder/physiopathology , Shoulder/physiology , Electromyography/methods , Muscle, Skeletal/physiopathology , Muscle, Skeletal/physiology , Range of Motion, Articular/physiology , Exercise Therapy/methods , Stroke/physiopathology , Robotics/methods , Biomechanical Phenomena/physiology , Adult
2.
PLoS One ; 19(5): e0303365, 2024.
Article En | MEDLINE | ID: mdl-38728246

INTRODUCTION/BACKGROUND: Neck pain is a burdensome condition associated with pain, disability, and economic cost. Neck pain has been associated with observable changes in neuromuscular function and biomechanics. Prior research shows impairments in kinematic control, including reduced mobility, velocity, and smoothness of cervical motion. However, the strength of association between these impairments and patient-reported pain and disability is unclear rendering development of novel and relevant rehabilitation strategies difficult. The aim of this systematic review is to synthesize existing evidence on the strength of association between clinical biomechanical metrics of neck function (ROM, strength, acceleration, accuracy, smoothness, etc.) and patient-reported neck pain and disability. METHODS/ANALYSIS: This protocol follows Cochrane guidelines and adheres to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses Protocols (PRISMA-P). MEDLINE, EMBASE, CINAHL, SPORTDiscus, Web of Science and Scopus will be searched, along with the gray literature, up to 20 November 2023, using terms and keywords derived from initial scoping searches. Observational studies, including cohorts and cross-sectional studies, that explore associations between clinical biomechanics of the neck and patient-reported outcomes of neck pain or disability will be included. Two reviewers will independently perform study selection, data extraction, and risk of bias assessment (National Institute of Health tool). Data will be synthesized using either a random effects meta-analytic approach or qualitatively using a modified Grading of Recommendations, Assessment, Development and Evaluation (GRADE) approach, dependent on the homogeneity of data available. DISCUSSION AND RELEVANCE: This review addresses a gap in the literature by systematically synthesizing findings on the relationship between neck function impairments and patient-reported outcomes. It will identify priorities for neck pain rehabilitation and gaps in current knowledge. DISSEMINATION: The results of this review will be disseminated through a peer-reviewed publication, conference presentation, and lay language summaries posted on an open-access website. TRIAL REGISTRATION: PROSPERO Registration number: CRD42023417317. https://www.crd.york.ac.uk/prospero/display_record.php?ID=CRD42023417317.


Cervical Vertebrae , Meta-Analysis as Topic , Neck Pain , Systematic Reviews as Topic , Humans , Neck Pain/physiopathology , Cervical Vertebrae/physiopathology , Biomechanical Phenomena , Range of Motion, Articular
3.
Medicine (Baltimore) ; 103(19): e38065, 2024 May 10.
Article En | MEDLINE | ID: mdl-38728521

Knee varus (KV) deformity leads to abnormal forces in the different compartments of the joint cavity and abnormal mechanical loading thus leading to knee osteoarthritis (KOA). This study used computer-aided design to create 3-dimensional simulation models of KOA with varying varus angles to analyze stress distribution within the knee joint cavity using finite element analysis for different varus KOA models and to compare intra-articular loads among these models. Additionally, we developed a cartilage loading model of static KV deformity to correlate with dynamic clinical cases of cartilage injury. Different KV angle models were accurately simulated with computer-aided design, and the KV angles were divided into (0°, 3°, 6°, 9°, 12°, 15°, and 18°) 7 knee models, and then processed with finite element software, and the Von-Mises stress distribution and peak values of the cartilage of the femoral condyles, medial tibial plateau, and lateral plateau were obtained by simulating the human body weight in axial loading while performing the static extension position. Finally, intraoperative endoscopy visualization of cartilage injuries in clinical cases corresponding to KV deformity subgroups was combined to find cartilage loading and injury correlations. With increasing varus angle, there was a significant increase in lower limb mechanical axial inward excursion and peak Von-Mises stress in the medial interstitial compartment. Analysis of patients' clinical data demonstrated a significant correlation between varus deformity angle and cartilage damage in the knee, medial plateau, and patellofemoral intercompartment. Larger varus deformity angles could be associated with higher medial cartilage stress loads and increased cartilage damage in the corresponding peak stress area. When the varus angle exceeds 6°, there is an increased risk of cartilage damage, emphasizing the importance of early surgical correction to prevent further deformity and restore knee function.


Cartilage, Articular , Finite Element Analysis , Knee Joint , Osteoarthritis, Knee , Humans , Osteoarthritis, Knee/physiopathology , Osteoarthritis, Knee/surgery , Cartilage, Articular/diagnostic imaging , Cartilage, Articular/pathology , Knee Joint/physiopathology , Male , Weight-Bearing/physiology , Biomechanical Phenomena , Middle Aged , Stress, Mechanical , Female , Computer Simulation , Aged
4.
BMC Vet Res ; 20(1): 188, 2024 May 10.
Article En | MEDLINE | ID: mdl-38730373

Femoral fractures are often considered lethal for adult horses because femur osteosynthesis is still a surgical challenge. For equine femur osteosynthesis, primary stability is essential, but the detailed physiological forces occurring in the hindlimb are largely unknown. The objective of this study was to create a numerical testing environment to evaluate equine femur osteosynthesis based on physiological conditions. The study was designed as a finite element analysis (FEA) of the femur using a musculoskeletal model of the loading situation in stance. Relevant forces were determined in the musculoskeletal model via optimization. The treatment of four different fracture types with an intramedullary nail was investigated in FEA with loading conditions derived from the model. The analyzed diaphyseal fracture types were a transverse (TR) fracture, two oblique fractures in different orientations (OB-ML: medial-lateral and OB-AP: anterior-posterior) and a "gap" fracture (GAP) without contact between the fragments. For the native femur, the most relevant areas of increased stress were located distally to the femoral head and proximally to the caudal side of the condyles. For all fracture types, the highest stresses in the implant material were present in the fracture-adjacent screws. Maximum compressive (-348 MPa) and tensile stress (197 MPa) were found for the GAP fracture, but material strength was not exceeded. The mathematical model was able to predict a load distribution in the femur of the standing horse and was used to assess the performance of internal fixation devices via FEA. The analyzed intramedullary nail and screws showed sufficient stability for all fracture types.


Femoral Fractures , Fracture Fixation, Internal , Hindlimb , Animals , Horses/physiology , Biomechanical Phenomena , Femoral Fractures/veterinary , Femoral Fractures/surgery , Fracture Fixation, Internal/veterinary , Fracture Fixation, Internal/methods , Hindlimb/surgery , Finite Element Analysis , Femur/surgery , Models, Biological , Weight-Bearing , Fracture Fixation, Intramedullary/veterinary , Fracture Fixation, Intramedullary/instrumentation
5.
BMC Oral Health ; 24(1): 545, 2024 May 10.
Article En | MEDLINE | ID: mdl-38730391

BACKGROUND: This Finite Element Analysis was conducted to analyze the biomechanical behaviors of titanium base abutments and several crown materials with respect to fatigue lifetime and stress distribution in implants and prosthetic components. METHODS: Five distinct designs of implant-supported single crowns were modeled, including a polyetheretherketone (PEEK), polymer-infiltrated ceramic network, monolithic lithium disilicate, and precrystallized and crystallized zirconia-reinforced lithium silicates supported by a titanium base abutment. For the static load, a 100 N oblique load was applied to the buccal incline of the palatal cusp of the maxillary right first premolar. The dynamic load was applied in the same way as in static loading with a frequency of 1 Hz. The principal stresses in the peripheral bone as well as the von Mises stresses and fatigue strength of the implants, abutments, prosthetic screws, and crowns were assessed. RESULTS: All of the models had comparable von Mises stress values from the implants and abutments, as well as comparable maximum and minimum principal stress values from the cortical and trabecular bones. The PEEK crown showed the lowest stress (46.89 MPa) in the cervical region. The prosthetic screws and implants exhibited the highest von Mises stress among the models. The lithium disilicate crown model had approximately 9.5 times more cycles to fatique values for implants and 1.7 times more cycles to fatique values for abutments than for the lowest ones. CONCLUSIONS: With the promise of at least ten years of clinical success and favorable stress distributions in implants and prosthetic components, clinicians can suggest using an implant-supported lithium disilicate crown with a titanium base abutment.


Benzophenones , Crowns , Dental Abutments , Dental Prosthesis, Implant-Supported , Dental Stress Analysis , Finite Element Analysis , Titanium , Titanium/chemistry , Humans , Dental Porcelain/chemistry , Polyethylene Glycols/chemistry , Dental Materials/chemistry , Polymers , Ketones/chemistry , Zirconium/chemistry , Dental Implants, Single-Tooth , Materials Testing , Dental Implant-Abutment Design , Biomechanical Phenomena
6.
Vestn Oftalmol ; 140(2): 78-82, 2024.
Article Ru | MEDLINE | ID: mdl-38742502

Diabetic vitreopapillary traction syndrome (VPT) is a variant of diabetic retinopathy (DR) that can lead to vision loss in advanced stages. This review reports on the biomechanics of the vitreous in the pathogenesis of proliferative DR, in particular diabetic VPT. The article analyzes and summarizes literature data, presents the views of different authors on this problem, and provides the results of Russian and foreign scientific research on this pathology. It is concluded that further research in this area can lead to a significant improvement in the results of therapy, timely diagnosis, and preservation of vision in patients with DR.


Diabetic Retinopathy , Vitreous Body , Humans , Diabetic Retinopathy/diagnosis , Diabetic Retinopathy/physiopathology , Diabetic Retinopathy/therapy , Vitreous Body/physiopathology , Biomechanical Phenomena , Syndrome , Vitreoretinopathy, Proliferative/physiopathology , Vitreoretinopathy, Proliferative/etiology , Vitreoretinopathy, Proliferative/diagnosis , Vitreoretinopathy, Proliferative/therapy
7.
BMC Oral Health ; 24(1): 561, 2024 May 14.
Article En | MEDLINE | ID: mdl-38745284

BACKGROUND: Prefabricated myofunctional appliance can guide tooth eruption, improve dentition alignment, correct myofunctional disorders and harmful oral habits. However, its application to skeletal discrepancy may result in unsatisfactory tooth inclination. This study aimed to construct a novel appliance with overjet design to avoid this side effect and investigated its shape and mechanical changes under occlusion using three-dimensional finite element method. METHODS: We established three samples of prefabricated myofunctional appliances. The first one was edge to edge without overjet, and the outer shield of both jaws were flattened. The second one was 3 mm overjet with stepped the outer shield. The last one was 3 mm overjet, and the outer shield of both jaws were flatted, which meant the front wall of lower jaw was strengthened with bumper, termed as lower bumper. A complete dentition model was applied to the study. 150 N occlusal force was applied to each type of appliance and the deformation displacement and the changes in stress was recorded. RESULTS: The deformation was significant in the incisors regions, especially in the vertical and lateral dimensions. The maximum displacements of 3 mm overjet with step shield group were 7.08 mm (vertical), 3.99 mm (lateral), and 2.90 mm (sagittal), while it decreased to 3.92 mm(vertical), 1.94 mm (lateral), and 1.55 mm (sagittal) in overjet with bumper group. Moreover, the upper molar regions exhibited higher vertical and sagittal displacement in 3 mm overjet with step shield group, which were 3.03 mm (vertical) and 1.99 mm (sagittal), and the bumper design could decrease the maximum displacement to 1.72 mm (vertical) and 0.72 mm (sagittal). In addition, the Von Mises stress of appliances was analyzed, and results indicated that 3 mm overjet with step shield generated higher stress than other groups, with the maximum Von Mises stress was 0.9387 MP, which were 0.5858 and 0.5657 MP in edge to edge group and 3 mm overjet with lower bumper group, respectively. CONCLUSION: The prefabricated myofunctional appliances may cause deformation during occlusion. Compared to step shield group, the application of lower bumper exhibited better resistance to occlusal force.


Finite Element Analysis , Orthodontic Appliance Design , Humans , Myofunctional Therapy/instrumentation , Myofunctional Therapy/methods , Bite Force , Imaging, Three-Dimensional/methods , Overbite/therapy , Stress, Mechanical , Mandible , Incisor , Biomechanical Phenomena
8.
BMJ Open ; 14(5): e077942, 2024 May 07.
Article En | MEDLINE | ID: mdl-38719321

INTRODUCTION: Even when total knee arthroplasty (TKA) is an extended treatment, most patients experience a suboptimal evolution after TKA. The objectives of this study are the following: (1) to determine the effectiveness of two different prosthesis stabilisation systems on the functionality in activities of daily life, and (2) to determine prognostic biomarkers of knee prosthesis function based on radiological information, quantification of cytokines, intra-articular markers and biomechanical functional evaluation to predict successful evolution. METHODS AND ANALYSIS: The PROKnee trial was designed as a randomised controlled patient-blinded trial with two parallel groups that are currently ongoing. The initial recruitment will be 99 patients scheduled for their first TKA, without previous prosthesis interventions in lower limbs, who will be randomly divided into two groups that differed in the stabilisation methodology incorporated in the knee prosthesis: the MEDIAL-pivot group and the CENTRAL-pivot group. The maximum walking speed will be reported as the primary outcome, and the secondary results will be patient-reported questionnaires related to physical status, cognitive and mental state, radiological test, laboratory analysis and biomechanical instrumented functional performance, such as the 6-minute walking test, timed up-and-go test, gait, sit-to-stand, step-over, and ability to step up and down stairs. All the results will be measured 1 week before TKA and at 1.5, 3, 6 and 12 months after surgery. ETHICS AND DISSEMINATION: All procedures were approved by the Ethical Committee for Research with Medicines of the University Clinical Hospital of Valencia on 8 October 2020 (order no. 2020/181). Participants are required to provide informed consent for the study and for the surgical procedure. All the data collected will be treated confidentially since they will be blinded and encrypted. The results from the trial will be published in international peer-reviewed scientific journals, regardless of whether these results are negative or inconclusive. TRIAL REGISTRATION NUMBER: ClinicalTrials.gov Registry (NCT04850300).


Activities of Daily Living , Arthroplasty, Replacement, Knee , Humans , Arthroplasty, Replacement, Knee/methods , Randomized Controlled Trials as Topic , Knee Prosthesis , Recovery of Function , Female , Male , Follow-Up Studies , Biomechanical Phenomena , Knee Joint/surgery , Knee Joint/physiopathology
9.
Sci Rep ; 14(1): 10465, 2024 05 07.
Article En | MEDLINE | ID: mdl-38714823

Balance impairment is associated gait dysfunction with several quantitative spatiotemporal gait parameters in patients with stroke. However, the link between balance impairments and joint kinematics during walking remains unclear. Clinical assessments and gait measurements using motion analysis system was conducted in 44 stroke patients. This study utilised principal component analysis to identify key joint kinematics characteristics of patients with stroke during walking using average joint angles of pelvis and bilateral lower limbs in every gait-cycle percentile related to balance impairments. Reconstructed kinematics showed the differences in joint kinematics in both paretic and nonparetic lower limbs that can be distinguished by balance impairment, particularly in the sagittal planes during swing phase. The impaired balance group exhibited greater joint variability in both the paretic and nonparetic limbs in the sagittal plane during entire gait phase and during terminal swing phase respectively compared with those with high balance scores. This study provides a more comprehensive understanding of stroke hemiparesis gait patterns and suggests considering both nonparetic and paretic limb function, as well as bilateral coordination in clinical practice. Principal component analysis can be a useful assessment tool to distinguish differences in balance impairment and dynamic symmetry during gait in patients with stroke.


Gait , Postural Balance , Principal Component Analysis , Stroke , Walking , Humans , Male , Female , Postural Balance/physiology , Stroke/physiopathology , Stroke/complications , Middle Aged , Walking/physiology , Aged , Biomechanical Phenomena , Gait/physiology , Gait Disorders, Neurologic/physiopathology , Gait Disorders, Neurologic/diagnosis , Gait Disorders, Neurologic/etiology , Adult
10.
Eur J Med Res ; 29(1): 264, 2024 May 03.
Article En | MEDLINE | ID: mdl-38698476

BACKGROUND: The fundamental prerequisite for prognostically favorable postoperative results of peripheral nerve repair is stable neurorrhaphy without interruption and gap formation. METHODS: This study evaluates 60 neurorrhaphies on femoral chicken nerves in terms of the procedure and the biomechanical properties. Sutured neurorrhaphies (n = 15) served as control and three sutureless adhesive-based nerve repair techniques: Fibrin glue (n = 15), Histoacryl glue (n = 15), and the novel polyurethane adhesive VIVO (n = 15). Tensile and elongation tests of neurorrhaphies were performed on a tensile testing machine at a displacement rate of 20 mm/min until failure. The maximum tensile force and elongation were recorded. RESULTS: All adhesive-based neurorrhaphies were significant faster in preparation compared to sutured anastomoses (p < 0.001). Neurorrhaphies by sutured (102.8 [cN]; p < 0.001), Histoacryl (91.5 [cN]; p < 0.001) and VIVO (45.47 [cN]; p < 0.05) withstood significant higher longitudinal tensile forces compared to fibrin glue (10.55 [cN]). VIVO, with △L/L0 of 6.96 [%], showed significantly higher elongation (p < 0.001) compared to neurorrhaphy using fibrin glue. CONCLUSION: Within the limitations of an in vitro study the adhesive-based neurorrhaphy technique with VIVO and Histoacryl have the biomechanical potential to offer alternatives to sutured neuroanastomosis because of their stability, and faster handling. Further in vivo studies are required to evaluate functional outcomes and confirm safety.


Anastomosis, Surgical , Chickens , Tensile Strength , Animals , Anastomosis, Surgical/methods , Biomechanical Phenomena , Tissue Adhesives/pharmacology , Fibrin Tissue Adhesive/pharmacology , Peripheral Nerves/surgery , Peripheral Nerves/physiology , Adhesives , Neurosurgical Procedures/methods
11.
Sci Rep ; 14(1): 10421, 2024 05 07.
Article En | MEDLINE | ID: mdl-38710897

Humans move their hands toward precise positions, a skill supported by the coordination of multiple joint movements, even in the presence of inherent redundancy. However, it remains unclear how the central nervous system learns the relationship between redundant joint movements and hand positions when starting from scratch. To address this question, a virtual-arm reaching task was performed in which participants were required to move a cursor corresponding to the hand of a virtual arm to a target. The joint angles of the virtual arm were determined by the heights of the participants' fingers. The results demonstrated that the participants moved the cursor to the target straighter and faster in the late phase than they did in the initial phase of learning. This improvement was accompanied by a reduction in the amount of angular changes in the virtual limb joint, predominantly characterized by an increased reliance on the virtual shoulder joint as opposed to the virtual wrist joint. These findings suggest that the central nervous system selects a combination of multijoint movements that minimize motor effort while learning novel upper-limb kinematics.


Arm , Learning , Movement , Humans , Biomechanical Phenomena , Arm/physiology , Male , Learning/physiology , Female , Movement/physiology , Adult , Young Adult , Psychomotor Performance/physiology , Wrist Joint/physiology
12.
Reprod Domest Anim ; 59(5): e14585, 2024 May.
Article En | MEDLINE | ID: mdl-38745503

The study investigated midpiece defects in sperm from a 5-year-old Brangus bull with a high rate of semen batch rejection, due to morphologically abnormal sperm, with no reduction in sperm kinematics. A comprehensive evaluation was conducted over a 16-month period, involving 28 ejaculates. Notably, despite the high proportion of midpiece defects (average 37.73%, from 3% to 58%), the study revealed stable sperm production, with no discernible differences in the kinematic data before and after cryopreservation. Electron microscopy identified discontinuities in the mitochondrial sheath, characteristic of midpiece aplasia (MPA). The anomalies were attributed to be of genetic origin, as other predisposing factors were absent. Additionally, the electron microscopy unveiled plasma membrane defects, vacuoles and chromatin decondensation, consistent with previous findings linking acrosome abnormalities with midpiece defects. The findings underscored the necessity of conducting thorough laboratory evaluations before releasing cryopreserved semen for commercialization. Despite substantial morphological alterations, the initial semen evaluation data indicated acceptable levels of sperm kinematics, emphasizing the resilience of sperm production to severe morphological changes. This case report serves as a contribution to the understanding of midpiece defects in bull sperm, emphasizing the need for meticulous evaluation and quality control in semen processing and commercialization.


Cryopreservation , Semen Analysis , Semen Preservation , Spermatozoa , Male , Animals , Cryopreservation/veterinary , Cattle , Semen Preservation/veterinary , Semen Analysis/veterinary , Spermatozoa/abnormalities , Spermatozoa/physiology , Biomechanical Phenomena , Sperm Midpiece , Sperm Motility , Acrosome
13.
Clin Oral Investig ; 28(6): 311, 2024 May 14.
Article En | MEDLINE | ID: mdl-38743171

OBJECTIVE: This study used image-based finite element analysis (FEA) to assess the biomechanical changes in mandibular first molars resulting from alterations in the position of the root canal isthmus. METHODS: A healthy mandibular first molar, characterized by two intact root canals and a cavity-free surface, was selected as the subject. A three-dimensional model for the molar was established using scanned images of the patient's mandibular teeth. Subsequently, four distinct finite element models were created, each representing varied root canal morphologies: non-isthmus (Group A), isthmus located at the upper 1/3 of the root (Group B), middle 1/3 of the root (Group C), and lower 1/3 of the root (Group D). A static load of 200 N was applied along the tooth's longitudinal axis on the occlusal surface to simulate regular chewing forces. The biomechanical assessment was conducted regarding the mechanical stress profile within the root dentin. The equivalent stress (Von Mises stress) was used to assess the biomechanical features of mandibular teeth under mechanical loading. RESULTS: In Group A (without an isthmus), the maximum stress was 22.2 MPa, while experimental groups with an isthmus exhibited higher stresses, reaching up to 29.4 MPa. All maximum stresses were concentrated near the apical foramen. The presence of the isthmus modified the stress distribution in the dentin wall of the tooth canal. Notably, dentin stresses at specific locations demonstrated differences: at 8 mm from the root tip, Group B: 13.6 MPa vs. Group A: 11.4 MPa; at 3 mm from the root tip, Group C: 14.2 MPa vs. Group A: 4.5 MPa; at 1 mm from the root tip, Group D: 25.1 MPa vs. Group A: 10.3 MPa. The maximum stress in the root canal dentin within the isthmus region was located either at the top or bottom of the isthmus. CONCLUSION: A root canal isthmus modifies the stress profile within the dentin. The maximum stress occurs near the apical foramen and significantly increases when the isthmus is located closer to the apical foramina.


Dental Pulp Cavity , Dental Stress Analysis , Finite Element Analysis , Mandible , Molar , Humans , Biomechanical Phenomena , Dental Pulp Cavity/anatomy & histology , Dental Stress Analysis/methods , Imaging, Three-Dimensional/methods , Stress, Mechanical
20.
PLoS One ; 19(5): e0303511, 2024.
Article En | MEDLINE | ID: mdl-38743738

The brachial plexus is a set of nerves that innervate the upper extremity and may become injured during the birthing process through an injury known as Neonatal Brachial Plexus Palsy. Studying the mechanisms of these injuries on infant cadavers is challenging due to the justifiable sensitivity surrounding testing. Thus, these specimens are generally unavailable to be used to investigate variations in brachial plexus injury mechanisms. Finite Element Models are an alternative way to investigate the response of the neonatal brachial plexus to loading. Finite Element Models allow a virtual representation of the neonatal brachial plexus to be developed and analyzed with dimensions and mechanical properties determined from experimental studies. Using ABAQUS software, a two-dimensional brachial plexus model was created to analyze how stresses and strains develop within the brachial plexus. The main objectives of this study were (1) to develop a model of the brachial plexus and validate it against previous literature, and (2) to analyze the effect of stress on the nerve roots based on variations in the angles between the nerve roots and the spinal cord. The predicted stress for C5 and C6 was calculated as 0.246 MPa and 0.250 MPa, respectively. C5 and C6 nerve roots experience the highest stress and the largest displacement in comparison to the lower nerve roots, which correlates with clinical patterns of injury. Even small (+/- 3 and 6 degrees) variations in nerve root angle significantly impacted the stress at the proximal nerve root. This model is the first step towards developing a complete three-dimensional model of the neonatal brachial plexus to provide the opportunity to more accurately assess the effect of the birth process on the stretch within the brachial plexus and the impact of biological variations in structure and properties on the risk of Neonatal Brachial Plexus Palsy.


Brachial Plexus , Finite Element Analysis , Brachial Plexus/injuries , Brachial Plexus/anatomy & histology , Humans , Infant, Newborn , Stress, Mechanical , Biomechanical Phenomena
...